Clinical trial · Observational
Prostate Cancer REsearch Using Cross-validation of Innovative Sampling, Integrating LC-MS/MS for Optimized Therapeutic Drug moNitoring
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
Applying Dried Blood Spots (DBS) techniques to pharmacokinetic analysis could significantly streamline the use of Therapeutic Drug Monitoring (TDM) in clinical practice. To establish DBS as a viable alternative sampling method, it is essential to demonstrate that results obtained from DBS analysis are reliable. This validation can be achieved through a cross-validation study. In this protocol, an original validated method, the plasma-based assay, serves as the "reference", while the alternative DBS-based analytical technique is the "comparator." The reliability will be defined analysing patients' samples with the new methods and comparing these results with those obtained with the reference LC-MS/MS (Liquid Chromatography-Mass Spectrometry) methods (in plasma). The possibility to apply DBS technique to pharmacokinetic analysis should largely facilitate the application of TDM to clinical practice.
Conditions
Conditions (1)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Prostate Cancer | Malignant Prostate Neoplasm | CURATED_EXACT | 0.92 |
Interventions
Interventions (0)
Data not yet available
Design
Arms and outcomes
Arms (0)
[]Primary outcomes (1)
- measure
- To assess the reliability of innovative analytical methods based on DBS sampling for the quantification of abiraterone, apalutamide, darolutamide, and enzalutamide
- timeFrame
- 24 months
- description
- The reliability will be assessed comparing results obtained with the new methods and with the reference LC-MS/MS methods (in plasma) evaluating the comprehensive results of the following analysis: 1. Calculation of Lin's concordance correlation coefficient (ρc) that quantifies the agreement between two measures of the same variable (e.g. chemical concentration); 2. Quantification of the mean difference and of the limits of agreement between the two methods with Bland-Altman method; 3. Evaluation of the slope and the intercept obtained using Passing-Bablok regression analysis; 4. Check for agreement with FDA/EMA guidelines requirements: the difference between the results obtained with the new method and the results obtained with the gold standard assay (% difference) should be within 20% in least two-thirds (67%) of the samples analyzed
Secondary outcomes (3)
- measure
- To collect preliminary data regarding intra-patient (consecutive samples collected from the same patient) variability of Cmin values;
- timeFrame
- 24 months
- description
- Intra-patient variation will be evaluated with intrapatient variation coefficient
Eligibility
Eligibility (as posted)
- Sex
- All
- Minimum age
- 18 Years
Show eligibility criteria text
Inclusion Criteria: * Patients treated with abiraterone, apalutamide, darolutamide, and enzalutamide according to the dosing regimens described in the Summary of Product Characteristics. The treatment cycle does not matter but patients should be at the steady state (see section 4.2);• Age ≥18; * Signed informed consent is required Exclusion Criteria: * Conditions that may limit the ability to adequately comply with the study procedures outlined in the protocol; * Refusal of informed consent; * Any condition that, in the investigator's judgment, could compromise appropriate participation in the study.
References
Publications (0)
Data not yet available