Clinical trial · Interventional
Totally Robotic Versus Surgeon-Assisted Robotic Lung Resection For Early-Stage NSCLC
Totally Robotic Versus Surgeon-Assisted Robotic Lung Resection For Early-Stage Non-Small Cell Lung Cancer: A Randomized Controlled Trial
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
Robotic-assisted thoracoscopic surgery (RTS) is safe and effective for patients with early-stage non-small cell lung cancer (NSCLC). During RTS, division, dissection, and sealing of lung tissue, bronchi, and blood vessels can be performed using handheld staplers with assistance from a bedside surgeon (Surgeon-Assisted), or totally robotically with robotic staplers and energy devices by the console surgeon (Totally Robotic). Totally Robotic lung resection enables the operating surgeon to perform the case independently, but its implication on costs and patient outcomes remains unknown. There also is, however, a lack of prospective research evaluating the costs of the two methods for dissection and vessel sealing in RTS. This RCT aims to evaluate the costs and perioperative patient outcomes of Totally Robotic lung resection using the Vessel Sealer Extend energy device (for vessels \<7mm) and the SureForm robotic stapler (Intervention) versus Surgeon-Assisted robotic lung resection using the Signia stapler (Control) during RTS for NSCLC using the da Vinci system.
Conditions
Conditions (1)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Lung Cancer | Malignant Lung Neoplasm | CURATED_EXACT | 0.92 |
Interventions
Interventions (2)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| Medtronic Signia Stapler | Device | — | UNRESOLVED |
| Vessel Sealer Extend Energy Device and SureForm Stapler | Device | — | UNRESOLVED |
Design
Arms and outcomes
Arms (2)
- type
- ACTIVE_COMPARATOR
- label
- Surgeon-Assisted
- description
- Patients randomized to this arm will undergo RTS with the Medtronic Signia Stapler.
- interventionNames
- Device: Medtronic Signia Stapler
- type
- EXPERIMENTAL
- label
- Totally Robotic
- description
- Patients randomized to this arm will undergo RTS with the Da Vinci Vessel Sealer Extend Energy Device and SureForm Stapler.
- interventionNames
- Device: Vessel Sealer Extend Energy Device and SureForm Stapler
Primary outcomes (1)
- measure
- Costs of Totally Robotic versus Surgeon-Assisted Robotic Lung Resection
- timeFrame
Eligibility
Eligibility (as posted)
- Sex
- All
- Minimum age
- 18 Years
- Maximum age
- 120 Years
Show eligibility criteria text
Inclusion Criteria: * Age between 18 and 120 years at time of consent * Ability to speak and understand English * Clinical stage I, II or IIIa NSCLC * Candidate for RTS, as determined by the operating surgeon Exclusion Criteria: * Anticoagulation with inability to cease anticoagulant therapy prior to surgery * Incurable coagulopathy * Systemic vascular disease or vasculitis * Not a candidate for RTS
References
Publications (0)
Data not yet available