Clinical trial · Observational
The Effect of Patient Position Changes on Advanced Cardiac Indices in Cancer Surgery
The Impact of Patient Position Changes on Advanced Hemodynamic Indices in Laparoscopic and Open Major Abdominal Cancer Surgeries
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
Esophageal Doppler Monitoring (Deltex CardioQ Esophageal Doppler Monitor, ODM) is used to manage patients' fluid therapy by non-invasively measuring continuous cardiac output with an esophageal probe. The aim of this study was to compare the effects of patient position changes on cardiac indices and vital signs in patients who underwent major abdominal cancer surgery with laparoscopic and open surgery using ODM.
Conditions
Conditions (3)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Abdominal Cancer | Malignant Abdominal Neoplasm | ALIAS | 0.90 |
| Blood Pressure | — | UNRESOLVED | — |
| Cardiac Indices | — | UNRESOLVED | — |
Interventions
Interventions (1)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| cardiac indices in supine and trendelenburg position | Procedure | — | UNRESOLVED |
Design
Arms and outcomes
Arms (2)
- label
- ODM measurements of patients undergoing open surgery in supine and trendelenburg position
- description
- After intubation, serial ODM measurements were performed in the supine and trendelenburg position of the patient and CO: Cardiac output, FTc: Flow time corrected, PV: Peak velocity, SD: Stroke distance values were recorded.
- interventionNames
- Procedure: cardiac indices in supine and trendelenburg position
- label
- ODM measurements of patients undergoing laparoscopic surgery in supine and trendelenburg position
- description
- After intubation, serial ODM measurements were performed in the supine and trendelenburg position of the patient and CO: Cardiac output, FTc: Flow time corrected, PV: Peak velocity, SD: Stroke distance values were recorded.
- interventionNames
- Procedure: cardiac indices in supine and trendelenburg position
Primary outcomes (7)
- measure
- Cardiac Output
Eligibility
Eligibility (as posted)
- Sex
- All
- Minimum age
- 18 Years
- Maximum age
- 99 Years
Show eligibility criteria text
Inclusion Criteria: * Elective operation * ASA 1-4 Exclusion Criteria: * Heart failure * Valvular heart disease, * Patients with symptomatic rhythm disturbances * ODM placement contraindicated (coagulopathy, oesophageal varices, known aortic aneurysm)
References
Publications (7)
- RESULTHeinink TP, Read DJ, Mitchell WK, Bhalla A, Lund JN, Phillips BE, Williams JP. Oesophageal Doppler guided optimization of cardiac output does not increase visceral microvascular blood flow in healthy volunteers. Clin Physiol Funct Imaging. 2018 Mar;38(2):213-219. doi: 10.1111/cpf.12401. Epub 2017 Feb 6. PMID 28168868
- RESULTYonis H, Bitker L, Aublanc M, Perinel Ragey S, Riad Z, Lissonde F, Louf-Durier A, Debord S, Gobert F, Tapponnier R, Guerin C, Richard JC. Change in cardiac output during Trendelenburg maneuver is a reliable predictor of fluid responsiveness in patients with acute respiratory distress syndrome in the prone position under protective ventilation. Crit Care. 2017 Dec 5;21(1):295. doi: 10.1186/s13054-017-1881-0. PMID 29208025
- RESULTHaas S, Haese A, Goetz AE, Kubitz JC. Haemodynamics and cardiac function during robotic-assisted laparoscopic prostatectomy in steep Trendelenburg position. Int J Med Robot. 2011 Dec;7(4):408-13. doi: 10.1002/rcs.410. Epub 2011 Aug 3. PMID 21815239
- RESULTConway DH, Hussain OA, Gall I. A comparison of noninvasive bioreactance with oesophageal Doppler estimation of stroke volume during open abdominal surgery: an observational study. Eur J Anaesthesiol. 2013 Aug;30(8):501-8. doi: 10.1097/EJA.0b013e3283603250. PMID 23549128
- RESULTKaye AD, Vadivelu N, Ahuja N, Mitra S, Silasi D, Urman RD. Anesthetic considerations in robotic-assisted gynecologic surgery. Ochsner J. 2013 Winter;13(4):517-24. PMID 24358000
- RESULTHuang L, Critchley LA. An assessment of two Doppler-based monitors to track cardiac output changes in anaesthetised patients undergoing major surgery. Anaesth Intensive Care. 2014 Sep;42(5):631-9. doi: 10.1177/0310057X1404200514. PMID 25233178
- DERIVEDArgun G, Sahin MK. The impact of patient position changes on advanced hemodynamic indices in laparoscopic and open major abdominal cancer surgeries: retrospective study. BMC Surg. 2025 Aug 6;25(1):341. doi: 10.1186/s12893-025-03064-8.