Clinical trial · Observational
Clinical Application of the J-PET Scanner Prototype
Clinical Use of a J-PET Scanner Prototype Made of Plastic Scintilators
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
Positron emission tomography (PET), an advanced diagnostic imaging technique, exploits the annihilation of positrons (e+) to delineate pathological alterations within diseased tissues. Integral to PET scanners are detector systems that transform gamma photons into fluorescent photons, thereby gleaning insights into the energy, time, and spatial distribution of gamma photons emanating from positron-emitting radiopharmaceuticals. Conventional PET scanners, bear a significant financial burden primarily due to their reliance on LSO (lutetium oxyorthosilicate) or LYSO (lutetium yttrium oxyorthosilicate) scintillation crystals. The exorbitant cost and limited availability of these crystal scintillators impede the widespread adoption of PET scanners. In a departure from conventional PET technology, the prototype J-PET scanner employed in this trial employs plastic scintillators, characterized by unique physical properties. This prototype is further equipped with bespoke software enabling three-photon imaging based on the annihilation of ortho-positronium (o-Ps) generated within diseased tissue. This study delves into the clinical applicability of PET scanners employing plastic scintillators, particularly investigating the feasibility of PET imaging using plastic scintillators where gamma quanta interact by mechanisms other than the photoelectric effect. Furthermore, this study endeavors to contemporaneously acquire and analyze data related to the lifetime of ortho-positronium (o-P) atoms emanating from routine radiopharmaceuticals. Additionally, it seeks to validate the utilization of a novel diagnostic indicator, termed the \"positron biomarker,\" through a prospective study, comparing its efficacy to conventional diagnostic PET scanning methodologies.
Conditions
Conditions (6)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Neuroendocrine Carcinoma | Neuroendocrine Carcinoma | ONTOLOGY_EXACT | 0.98 |
| Neuroendocrine Tumors | Neuroendocrine Tumor | ONTOLOGY_EXACT | 0.90 |
| Prostate Cancer | Malignant Prostate Neoplasm | CURATED_EXACT | 0.92 |
| Prostate Cancer Metastatic | — | UNRESOLVED | — |
| Prostatic Hyperplasia | Benign Prostatic Hyperplasia | ALIAS | 0.90 |
| Prostatic Neoplasms | Prostate Neoplasm | ALIAS | 0.90 |
Interventions
Interventions (1)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| J-PET scan | Diagnostic Test | — | UNRESOLVED |
Design
Arms and outcomes
Arms (1)
- label
- J-PET group
- description
- The patient is referred for a PET/CT scan, in accordance with recognized indications for examining the brain or the entire body.
- interventionNames
- Diagnostic Test: J-PET scan
Primary outcomes (1)
- measure
- Intraclass correlation coefficient (ICC)
- timeFrame
- Initial analyzes will last 12 weeks
- description
- ICC for Cancer Stage using the union for international cancer control (UICC) TNM (T= tumor, N= nodal stage, M = metastasis) System (8th Edition) for plastic scanner positron emission and computed tomography (J-PET/CT) exams compared to the standard of care (SOC) full-dose PET/CT as assessed by a panel of physicians
Secondary outcomes (4)
- measure
- Image quality
- timeFrame
- after 3 months following scan
Eligibility
Eligibility (as posted)
- Sex
- All
- Minimum age
- 18 Years
Show eligibility criteria text
Inclusion Criteria: * The patient is referred for a PET/CT scan, in accordance with recognized indications for examining the entire body. * Age over 18 years * Informed, voluntary consent to participate in the study Exclusion Criteria: * Pregnant women, breastfeeding women * People with a previously diagnosed allergy to radiopharmaceuticals * Age under 18 years * Lack of cooperation with the patient * Lack of informed consent to participate in the study
References
Publications (6)
- BACKGROUNDMoskal P, Dulski K, Chug N, Curceanu C, Czerwinski E, Dadgar M, Gajewski J, Gajos A, Grudzien G, Hiesmayr BC, Kacprzak K, Kaplon L, Karimi H, Klimaszewski K, Korcyl G, Kowalski P, Kozik T, Krawczyk N, Krzemien W, Kubicz E, Malczak P, Niedzwiecki S, Pawlik-Niedzwiecka M, Pedziwiatr M, Raczynski L, Raj J, Rucinski A, Sharma S, Shivani, Shopa RY, Silarski M, Skurzok M, Stepien EL, Szczepanek M, Tayefi F, Wislicki W. Positronium imaging with the novel multiphoton PET scanner. Sci Adv. 2021 Oct 15;7(42):eabh4394. doi: 10.1126/sciadv.abh4394. Epub 2021 Oct 13. PMID 34644101
- BACKGROUNDMoskal P, Stepien EL. Prospects and Clinical Perspectives of Total-Body PET Imaging Using Plastic Scintillators. PET Clin. 2020 Oct;15(4):439-452. doi: 10.1016/j.cpet.2020.06.009. Epub 2020 Jul 29. PMID 32739047
- BACKGROUNDMoskal P, Kubicz E, Grudzien G, Czerwinski E, Dulski K, Leszczynski B, Niedzwiecki S, Stepien EL. Developing a novel positronium biomarker for cardiac myxoma imaging. EJNMMI Phys. 2023 Mar 24;10(1):22. doi: 10.1186/s40658-023-00543-w. PMID 36959477
- BACKGROUNDDadgar M, Parzych S, Baran J, Chug N, Curceanu C, Czerwinski E, Dulski K, Elyan K, Gajos A, Hiesmayr BC, Kaplon L, Klimaszewski K, Konieczka P, Korcyl G, Kozik T, Krzemien W, Kumar D, Niedzwiecki S, Panek D, Perez Del Rio E, Raczynski L, Sharma S, Shivani S, Shopa RY, Skurzok M, Stepien EL, Tayefi Ardebili F, Tayefi Ardebili K, Vandenberghe S, Wislicki W, Moskal P. Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators. EJNMMI Phys. 2023 Oct 11;10(1):62. doi: 10.1186/s40658-023-00572-5. PMID 37819578
- BACKGROUNDMoskal P, Kisielewska D, Curceanu C, Czerwinski E, Dulski K, Gajos A, Gorgol M, Hiesmayr B, Jasinska B, Kacprzak K, Kaplon L, Korcyl G, Kowalski P, Krzemien W, Kozik T, Kubicz E, Mohammed M, Niedzwiecki S, Palka M, Pawlik-Niedzwiecka M, Raczynski L, Raj J, Sharma S, Shivani, Shopa RY, Silarski M, Skurzok M, Stepien E, Wislicki W, Zgardzinska B. Feasibility study of the positronium imaging with the J-PET tomograph. Phys Med Biol. 2019 Mar 7;64(5):055017. doi: 10.1088/1361-6560/aafe20.