Clinical trial · Interventional
MR Correlated Spectroscopic Imaging for Diagnosing Breast Cancer
Non-Uniformly Sampled MR Correlated Spectroscopic Imaging in Breast Cancer and Nonlinear Reconstruction
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
This trial studies how well an imaging technique called magnetic resonance (MR) spectroscopic imaging works in identifying breast cancer in women with benign or suspicious areas in the breast. Magnetic resonance imaging (MRI) is a diagnostic tool used to investigate the location of tumors in different organs. Since radiological pictures do not have sufficient information for tumor grades, invasive procedure such as biopsy is performed on patients with breast cancers for diagnosis. Breast tissue contains water, fat, and chemicals known as metabolites. MR spectroscopic imaging may help to characterize the various breast metabolite steady state levels and identify the differences between necrosis and tumor recurrence, which is difficult using radiological procedures such as MRI.
Conditions
Conditions (3)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Benign Breast Neoplasm | Benign Breast Neoplasm | ONTOLOGY_EXACT | 0.98 |
| Breast Carcinoma | Breast Carcinoma | ONTOLOGY_EXACT | 0.98 |
| Malignant Breast Neoplasm | Malignant Breast Neoplasm | ONTOLOGY_EXACT | 0.98 |
Interventions
Interventions (2)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| Diffusion Weighted Imaging | Procedure | — | UNRESOLVED |
| Magnetic Resonance Spectroscopic Imaging | Procedure | — | UNRESOLVED |
Design
Arms and outcomes
Arms (1)
- type
- EXPERIMENTAL
- label
- Diagnostic (DWI, magnetic resonance spectroscopic imaging)
- description
- Participants undergo DWI over 15 minutes and MR spectroscopic imaging over 45 minutes.
- interventionNames
- Procedure: Diffusion Weighted Imaging
- Procedure: Magnetic Resonance Spectroscopic Imaging
Primary outcomes (1)
- measure
- Apparent diffusion coefficient (ADC) maps
- timeFrame
- At the time of imaging
- description
- ADC maps will be calculated from diffusion weighted (DW) images by using linear regression of logarithmic intensities by using software for combinations of two, three, four, and five DW images with different b values. ADC maps will also be calculated for the remaining combinations of up to 10 evenly distributed b values. In total, 501 value combinations will be automatically processed and analyzed.
Eligibility
Eligibility (as posted)
- Sex
- Female
- Minimum age
- 18 Years
- Maximum age
- 80 Years
Show eligibility criteria text
Inclusion Criteria: * Malignant tumor subjects must have malignant needle biopsy results with concordant imaging and pathological findings. * Benign tumor subjects must have benign needle biopsy results. Benign subjects will only include those with concordant benign imaging and pathological findings. * Control subjects: healthy and have no previous history of any type of cancers. * The women should be able to read and understand English. Hence, non-English speaking subjects will be excluded. However, if there will be a necessity of translating the written informed consent form in the subject's mother tongue (such as Hispanic, Chinese, Persian, Indian, etc.), the translated consent form will be submitted for expedited approval to the office of University of California, Los Angeles (UCLA) Institutional Review Board (IRB). Exclusion Criteria: * Pregnant women will be excluded. * Breast feeding women. * MR incompatible items: cardiac pacemaker, aneurysm clip, heart valve prosthesis, nitroglycerin transdermal patch, implanted cardiac defibrillator, implanted electrode, including pacing wires, cochlear implant, other, implanted drug infusion device, implanted insulin pump, intravascular coil, filter or stent: (e.g., Gianturco coil, Gunther inferior vena cava \[IVC\] filter, etc.), intraventricular shunt, neurostimulator/biostimulator, Swan-Ganz catheter, any type of electronic, mechanical or magnetic implant, any type of implant held in place by a magnet, artificial limb or joint, contraceptive device (e.g., intrauterine device \[IUD\], diaphragm), dentures, ear implant, eye/orbital implant, foreign body (e.g., shrapnel, bullet, etc.), halo vest or metallic cervical fixation device, orthopedic item (for example: pins, rods, screws, clips, plates, wires, etc.), surgical clip or staple, vascular access port, wire mesh, hearing aid (must remove prior to the exam), tattooed eyeliner (a small percentage of patients with tattooed eyeliner have experienced transient skin irritation in association with MRI). The patients using transdermal patches will be asked to remove the patch and will be excluded if the patch cannot be removed.
References
Publications (0)
Data not yet available