Clinical trial · Interventional
Uterine Manipulator Versus no Uterine Manipulator in Endometrial Cancer Trial
Randomized Controlled Trial on the Oncologic Outcomes of Use Versus Not Use of the Uterine Manipulator in the Surgical Treatment of Apparent Uterine-confined Endometrial Carcinoma
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
Minimally invasive surgery is the recommended approach in endometrial cancer (EC) patients based on the results of two randomized controlled trials, given its advantages without compromised oncologic outcomes. The uterine manipulator is commonly used in benign and malignant pathologies to perform a laparoscopic or robotic hysterectomy. However, although regularly used, the uterine manipulator adoption in EC is a controversial technical aspect due to the raised concerns regarding the possible risk of disruption of the tumor mass, the spread of malignant cells, and seeding of the disease, particularly at the level of the vaginal cuff or spread of tumor cells, with increased risk of recurrence and death due to EC. On that basis, given that hysterectomy without a uterine manipulator is feasible, only a randomized controlled trial comparing oncologic outcomes in EC patients after use versus not use of the uterine manipulator will be able to provide high-quality evidence to answer this critical question and allow or exclude the use of a uterine manipulator during minimally invasive hysterectomy for EC.
Conditions
Conditions (1)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Endometrial Neoplasms | Endometrial Neoplasm | ONTOLOGY_EXACT | 0.98 |
Interventions
Interventions (1)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| Uterine manipulator use | Device | — | UNRESOLVED |
Design
Arms and outcomes
Arms (2)
- type
- EXPERIMENTAL
- label
- Total hysterectomy with a uterine manipulator
- description
- Total hysterectomy with bilateral salpingo-oophorectomy performed with the use of a uterine manipulator during surgery.
- interventionNames
- Device: Uterine manipulator use
- type
- NO_INTERVENTION
- label
- Total hysterectomy without a uterine manipulator
- description
- Total hysterectomy with bilateral salpingo-oophorectomy performed without the use of a uterine manipulator during surgery.
Primary outcomes (1)
- measure
- Recurrence-free survival
- timeFrame
- Each follow-up visit, up to 4 years from the day of surgery
- description
Eligibility
Eligibility (as posted)
- Sex
- Female
- Minimum age
- 18 Years
- Maximum age
- 100 Years
Show eligibility criteria text
Inclusion Criteria: * Diagnosis of Endometrial Cancer of any histology (including carcinosarcoma) and grade * Planned surgical treatment including hysterectomy and bilateral salpingo-oophorectomy (ovarian preservation in selected patients is not an exclusion criterion) * Age ≥ 18 years * No preoperative evidence of extrauterine disease (Clinical stage IIIA, IIIB) * No preoperative evidence of suspicious lymph nodes (Clinical stage IIIC) * No preoperative evidence of distant metastasis (Clinical stage IV) * Approved and signed informed consent Exclusion Criteria: * Neoadjuvant therapy * Synchronous or previous (\< 5 years) invasive cancer, not including non-melanoma skin cancer * Fertility preservation * World Health Organization performance score \> 2 * Uterine sarcoma * Previous pelvic/abdominal radiotherapy, hormone therapy for cancer (\< 5 years), chemotherapy (\< 5 years), pelvic or paraaortic lymphadenectomy, or retroperitoneal surgery * Inadequate bone marrow function (white blood cells \<3·0×109/L, platelets \<100×109/L) * Inadequate liver function (bilirubin \>1.5×upper normal limit \[UNL\], aspartate aminotransferase, and alanine aminotransferase \>2.5 × UNL) * Inadequate kidney function (creatinine clearance \< 60 mL per min calculated according to Cockcroft-Gault 10 or \< 50 mL per min Ethylenediaminetetraacetic acid clearance) * Intraoperative evidence of stage IV disease
References
Publications (6)
- BACKGROUNDConcin N, Matias-Guiu X, Vergote I, Cibula D, Mirza MR, Marnitz S, Ledermann J, Bosse T, Chargari C, Fagotti A, Fotopoulou C, Gonzalez Martin A, Lax S, Lorusso D, Marth C, Morice P, Nout RA, O'Donnell D, Querleu D, Raspollini MR, Sehouli J, Sturdza A, Taylor A, Westermann A, Wimberger P, Colombo N, Planchamp F, Creutzberg CL. ESGO/ESTRO/ESP guidelines for the management of patients with endometrial carcinoma. Int J Gynecol Cancer. 2021 Jan;31(1):12-39. doi: 10.1136/ijgc-2020-002230. Epub 2020 Dec 18. PMID 33397713
- BACKGROUNDvan den Haak L, Alleblas C, Nieboer TE, Rhemrev JP, Jansen FW. Efficacy and safety of uterine manipulators in laparoscopic surgery: a review. Arch Gynecol Obstet. 2015 Nov;292(5):1003-11. doi: 10.1007/s00404-015-3727-9. Epub 2015 May 13. PMID 25967852
- BACKGROUNDUccella S, Cianci S, Gueli Alletti S. Uterine manipulator in endometrial cancer: we are still far from the answer. Am J Obstet Gynecol. 2021 Mar;224(3):332. doi: 10.1016/j.ajog.2020.09.049. Epub 2020 Nov 15. No abstract available. PMID 33207238
- BACKGROUNDUccella S, Bonzini M, Malzoni M, Fanfani F, Palomba S, Aletti G, Corrado G, Ceccaroni M, Seracchioli R, Shakir F, Ferrero A, Berretta R, Tinelli R, Vizza E, Roviglione G, Casarella L, Volpi E, Cicinelli E, Scambia G, Ghezzi F. The effect of a uterine manipulator on the recurrence and mortality of endometrial cancer: a multi-centric study by the Italian Society of Gynecological Endoscopy. Am J Obstet Gynecol. 2017 Jun;216(6):592.e1-592.e11. doi: 10.1016/j.ajog.2017.01.027. Epub 2017 Jan 29. PMID 28147240
- BACKGROUNDPadilla-Iserte P, Lago V, Tauste C, Diaz-Feijoo B, Gil-Moreno A, Oliver R, Coronado P, Martin-Salamanca MB, Pantoja-Garrido M, Marcos-Sanmartin J, Gilabert-Estelles J, Lorenzo C, Cazorla E, Roldan-Rivas F, Rodriguez-Hernandez JR, Sanchez L, Muruzabal JC, Hervas D, Domingo S; Spanish Society of Gynecology and Obstetrics Spanish Investigational Network Gynecologic Oncology Group. Impact of uterine manipulator on oncological outcome in endometrial cancer surgery. Am J Obstet Gynecol. 2021 Jan;224(1):65.e1-65.e11. doi: 10.1016/j.ajog.2020.07.025. Epub 2020 Jul 18.