Clinical trial · Observational
Real-time Diagnosis of Diminutive Colorectal Polyps Using AI
Real Time Computer-aided Diagnosis (CADx) of Diminutive Colorectal Polyps Using Artificial Intelligence
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
Correct endoscopic prediction of the histopathology and differentiation between benign, pre-malignant, and malignant colorectal polyps (optical diagnosis) remains difficult. Artificial intelligence has great potential in image analysis in gastrointestinal endoscopy. Aim of this study is to investigate the real-time diagnostic performance of AI4CRP for the classification of diminutive colorectal polyps, and to compare it with the real-time diagnostic performance of commercially available CADx systems.
Conditions
Conditions (2)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Colorectal Neoplasms | Colorectal Neoplasm | ONTOLOGY_EXACT | 0.98 |
| Colorectal Polyp | — | UNRESOLVED | — |
Interventions
Interventions (1)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| Computer-aided diagnosis (CADx) systems | Device | — | UNRESOLVED |
Design
Arms and outcomes
Arms (1)
- label
- Gastroenterology patients
- description
- Patient receiving a colonoscopy because of regular care will be considered eligible for inclusion if at least one diminutive colorectal polyp is encountered during the colonoscopy. Patients receive an endoscopic procedure in the context of the Dutch national screening program, because of gastrointestinal symptoms, or because of follow-up of previously diagnosed bowel diseases. Colonoscopies will be executed using Fujifilm endoscopy systems (Fujifilm® Corporation, Tokyo, Japan), using Pentax endoscopy systems (Pentax Medical®, Hamburg, Germany), and using Olympus endoscopy systems (Olympus®, Tokyo, Japan).
- interventionNames
- Device: Computer-aided diagnosis (CADx) systems
Primary outcomes (8)
- measure
- Technical feasibility of real-time use of AI4CRP.
- timeFrame
- 6 months
- description
- The technical feasibility of real-time use of AI4CRP in the endoscopy suite regarding a proper reception of the video output from the local endoscopy processor towards AI4CRP (in high definition quality, without any delays in time).
- measure
Eligibility
Eligibility (as posted)
- Sex
- All
- Minimum age
- 18 Years
Show eligibility criteria text
Inclusion Criteria: * Age \>18 years; * Patients with at least one colorectal polyps encountered during colonoscopy; * Patients referred for a colonoscopy by the Dutch bowel cancer screening program, patients undergoing a colonoscopy for endoscopic surveillance, or patients undergoing a colonoscopy because of complaints; * Written informed consent. Exclusion Criteria: * Patients with prior history of inflammatory bowel diseases (IBD) or polyposis syndromes; * Patients with inadequate bowel preparations after adequate washing, suctioning, and cleaning manoeuvres have been performed by the endoscopist; * Patients undergoing an emergency colonoscopy; * Written objection in the patient file for participation in scientific research.
References
Publications (0)
Data not yet available