Clinical trial · Observational
Safety and Efficacy of DEB-TACE Performed With a Novel Reflux-control Microcatheter in Patients With HCC
A Single Center Experience:Safety and Efficacy of DEB-TACE Performed With a Novel Reflux-control Microcatheter in Patients With Early and Intermediate HCC.
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
BACKGROUND: Hepatocellular carcinoma is the fifth most frequent cancer in the world, with a diagnosis of more than 500,000 new cases per year. It is considered the third leading cause of cancer mortality and presents well-defined risk factors. Liver cirrhosis is the main risk factor for developing HCC, therefore screening programs in cirrhotic patients will allow the early diagnosis of this neoplasia. Despite this, most HCCs are diagnosed at a stage in which the application of curative therapies is no longer possible. Hepatic transarterial chemoembolization (TACE) belongs to the arterially directed embolization therapies for the treatment of unresectable early-to-advanced hepatocellular carcinoma (HCC). It is the only therapy that has shown to improve survival in intermediate-stage HCC. Drug-eluting beads (DEB)-TACE has shown to provide slow drug elution, reduced liver and systemic toxicity, increased local drug concentration, and tissue necrosis. Aside from TACE, other transarterial options include bland embolization, or hepatic artery embolization (HAE), and transarterial radioembolization (TARE). All have an acceptable safety profile, and each has its associated procedural and peri-procedural complications. One potential complication that may occur during all embolization procedures is when the embolic material migrates outside of the desired treatment area, leading to non-target embolization (NTE). In fact, when collateral vessels are embolized, there is a risk that these may be feeders of non-target tissue or organs. NTE following TACE in particular may lead to a double-layer problem: dangerous components affecting healthy tissue, one ischemic and one related to cytotoxicity from the chemotherapeutic agent, which may have clinical consequences, and potential incomplete treatment of the lesion (due to beads being "deviated" from target). NTE is highly recognized, but often thought to be uncommon, and although different complications can be caused by it, there may appear to be no evidence of NTE during the intraprocedural imaging. To avoid the complications due to NTE, apart from the importance of the pre-, intra- and post-procedural imaging, and the thorough study of the anatomical picture, the catheters/microcatheters should also be chosen with reason and care. In particular, selective catheterization should be achieved by placing the microcatheter tip as close as possible to the target, through the specific branch/branches supplying it. However, even with the microcatheter selectively positioned in the vessel to be embolized, the risk of NTE might not be eliminated, since it could happen as a result of changes in flow dynamics that occur during embolization, particularly when the endpoint is stasis. These changes could result in reflux into non-target territories and, as such, might be better prevented with the use of microcatheters intended to reduce reflux. To this purpose, the use of a dedicated delivery device should be taken into consideration, in order to optimize and save time during the procedure. Microcatheters are commonly used during most arterial embolization procedures, and as explained above, there is a strong rationale to use a reflux-control microcatheter - like Sequre - for DEB-TACE. The main expectation is to achieve technical success with Sequre in all patients with a reachable target lesion, with the intent not only to minimize potential damage to surrounding tissue, but also to potentially deliver more treatment embolics, as all the beads are (re)directed towards the target. The use of small diameter particles (100 micron-TANDEM ® spheres), induces superior tumor necrosis response (Urbano et al., European Journal of Radiology, 2020); with the synergistic effect of being administered through the SEQURE anti-reflux protection system, there is reason to believe that it will be possible to administer maximum doses of doxorubicin, while avoiding the occlusion of non-target arterial segments (SYNERGIC EFFECT). STUDY PROPOSAL: We propose a prospective observational study with data collection from a single center (Virgen de las Nieves University Hospital-Granada), for a period that ranges October 2020-December 2021. Here summarized the inclusion criteria and contraindications: Inclusion criteria * BCLC B and or some case BCLC A * Both genders * Over 18 years. * Bilirubin less than 3 gr/dl. * No contraindications to the use of iodinated contrast * Absence of chronic kidney disease * ECOG 0-1. * Absence of encephalopathy. * Informed consent. Contraindications * Advanced liver disease. * Thrombosis or reversal of portal flow. * Vascular invasion. * Extrahepatic spread. * Contraindication to administration of cytostatics. * Contraindication to angiographic procedure.
Conditions
Conditions (2)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Hepatocellular Carcinoma | Hepatocellular Carcinoma | ONTOLOGY_EXACT | 0.98 |
| Liver Cancer | Malignant Liver Neoplasm | CURATED_EXACT | 0.92 |
Interventions
Interventions (1)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| Chemoembolization with preloaded microparticles 100 micron and reflux control microcatheter | Combination Product | — | UNRESOLVED |
Design
Arms and outcomes
Arms (1)
- label
- Patients with hepatocellular carcinoma treated with TAMDEM® 100 micron and SEQURE® microcatheter
- description
- Patients included in this study and with chemoembolization indications will be superselective embolized using TAMDEM® 100 micron preloaded particles (Doxorubicin) and SEQURE® microcatheter combination (SYNERGIC EFFECT). Objective tumoral response and 30 days-complications (Safety) are primary outcomes.
- interventionNames
- Combination Product: Chemoembolization with preloaded microparticles 100 micron and reflux control microcatheter
Primary outcomes (6)
- measure
- Objective Response Rate (ORR)
- timeFrame
- Assessed at 3 months after patient inclusion
- description
- ORR is defined as a complete or partial response among total of treated cases, according to mRECIST evaluated by CT or MRI. The value of these data is a percentage considering tumour diameter before and after treatment.
- measure
- Objective Response Rate (ORR)
- timeFrame
Eligibility
Eligibility (as posted)
- Sex
- All
- Minimum age
- 18 Years
Show eligibility criteria text
Inclusion Criteria: * BCLC B and or some case BCLC A * Both genders * Over 18 years. * Bilirubin less than 3 gr/dl. * No contraindications to the use of iodinated contrast * Absence of chronic kidney disease * ECOG 0-1. * Absence of encephalopathy. * Informed consent. Exclusion Criteria: * Advanced liver disease. * Thrombosis or reversal of portal flow. * Vascular invasion. * Extrahepatic spread. * Contraindication to administration of cytostatics. * Contraindication to angiographic procedure.
References
Publications (5)
- BACKGROUNDDelicque J, Guiu B, Boulin M, Schwanz H, Piron L, Cassinotto C. Liver chemoembolization of hepatocellular carcinoma using TANDEM(R) microspheres. Future Oncol. 2018 Nov;14(26):2761-2772. doi: 10.2217/fon-2018-0237. Epub 2018 Jun 28. PMID 29953255
- RESULTLammer J, Malagari K, Vogl T, Pilleul F, Denys A, Watkinson A, Pitton M, Sergent G, Pfammatter T, Terraz S, Benhamou Y, Avajon Y, Gruenberger T, Pomoni M, Langenberger H, Schuchmann M, Dumortier J, Mueller C, Chevallier P, Lencioni R; PRECISION V Investigators. Prospective randomized study of doxorubicin-eluting-bead embolization in the treatment of hepatocellular carcinoma: results of the PRECISION V study. Cardiovasc Intervent Radiol. 2010 Feb;33(1):41-52. doi: 10.1007/s00270-009-9711-7. Epub 2009 Nov 12. PMID 19908093
- RESULTUrbano J, Echevarria-Uraga JJ, Ciampi-Dopazo JJ, Sanchez-Corral JA, Cobos Alonso J, Anton-Ladislao A, Pena-Baranda B, Nacarino-Mejias V, Gonzalez-Costero R, Munoz Ruiz-Canela JJ, Perez-Cuesta J, Lanciego C, de Gregorio MA. Multicentre prospective study of drug-eluting bead chemoembolisation safety using tightly calibrated small microspheres in non-resectable hepatocellular carcinoma. Eur J Radiol. 2020 May;126:108966. doi: 10.1016/j.ejrad.2020.108966. Epub 2020 Mar 19. PMID 32278280
- RESULTAliberti C, Carandina R, Lonardi S, Dadduzio V, Vitale A, Gringeri E, Zanus G, Cillo U. Transarterial Chemoembolization with Small Drug-Eluting Beads in Patients with Hepatocellular Carcinoma: Experience from a Cohort of 421 Patients at an Italian Center. J Vasc Interv Radiol. 2017 Nov;28(11):1495-1502. doi: 10.1016/j.jvir.2017.07.020. Epub 2017 Sep 18. PMID 28927662
- RESULTLopez-Benitez R, Richter GM, Kauczor HU, Stampfl S, Kladeck J, Radeleff BA, Neukamm M, Hallscheidt PJ. Analysis of nontarget embolization mechanisms during embolization and chemoembolization procedures. Cardiovasc Intervent Radiol. 2009 Jul;32(4):615-22. doi: 10.1007/s00270-009-9568-9. Epub 2009 Apr 23. PMID 19387732