Summary
Brief summary (as posted)
Capability of oxytocin in improving the efficacy of MRI-HIFU is studied. Patients undergoing MRI-HIFU treatment are given oxytocin during treatment and the efficacy of the treatment will be analysed by patient reported symptom questionnaires and imaging data.
Conditions
Conditions (2)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Adenomyosis | — | UNRESOLVED | — |
| Fibroid | Leiomyoma | ALIAS | 0.90 |
Interventions
Interventions (1)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| Oxytocin | Drug | — | UNRESOLVED |
Design
Arms and outcomes
Arms (1)
- type
- EXPERIMENTAL
- label
- Patients treated with oxytocin during MRI-HIFU
- interventionNames
- Drug: Oxytocin
Primary outcomes (3)
- measure
- NPV
- timeFrame
- up to one year
- description
- non perfused volume (percentage of fibroid destroyed)
- measure
- duration of MRI-HIFU
- timeFrame
- up to one year
- description
- duration of MRI-HIFU treatment
- measure
- UFS-Qol
- timeFrame
Eligibility
Eligibility (as posted)
- Sex
- Female
- Minimum age
- 18 Years
- Maximum age
- 50 Years
Show eligibility criteria text
Inclusion Criteria: * Patients undergoing MRI-HIFU -treatment * Patients assessed for suitability to MRI-HIFU treatment * willingness to participate in trial Exclusion Criteria: * Known allergy to Syntocinon/oxytocin * Elevated blood pressure * ischemic heart disease * Long QT- interval
References
Publications (2)
- DERIVEDOtonkoski S, Viitala A, Komar G, Sainio T, Yanovskiy A, Blanco Sequieros R, Perheentupa A, Joronen K. Magnetic resonance guided high intensity focused ultrasound (MR-HIFU) effectively reduces fibroid-related symptoms and improves quality of life-A prospective single-centre 12-month follow-up study. Acta Obstet Gynecol Scand. 2025 Jun;104(6):1172-1180. doi: 10.1111/aogs.15086. Epub 2025 Apr 29. PMID 40302212
- DERIVEDOtonkoski S, Sainio T, Komar G, Suomi V, Saunavaara J, Blanco Sequeiros R, Perheentupa A, Joronen K. Oxytocin selectively reduces blood flow in uterine fibroids without an effect on myometrial blood flow: a dynamic contrast enhanced MRI evaluation. Int J Hyperthermia. 2020;37(1):1293-1300. doi: 10.1080/02656736.2020.1846792. PMID 33207939