Clinical trial · Interventional
MRI Only Radiation Therapy With CPAP
MRI-only Radiation Therapy Workflow With Continuous Positive Airway Pressure (CPAP) for Motion Management in the Abdomen
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Why stopped (as posted): Study terminated prematurely well short of enrollment target. Only 5 health participants were enrolled
Summary
Brief summary (as posted)
The goal of this imaging study is to evaluate and improve the treatment planning techniques for abdominal radiation therapy. To accurately treat a tumor with radiation, Computed Tomography (CT) and Magnetic Resonance Images (MRI) are used to distinguish a tumor from normal, healthy tissue. However the quality of these images can be distorted by motion from breathing. To decrease motion, a patient may be asked to hold their breath or compress the abdomen, but currently there is no standard or best management option for all patients. This study will explore the use continuous positive airway pressure (CPAP), a pressurized breathing mask, during MRI or CT imaging to decrease motion in the abdomen and produce higher quality images. With these additional images, we will also explore the feasibility of creating treatment plans using the CPAP MRI images alone.
Conditions
Conditions (2)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Carcinoma Liver | — | UNRESOLVED | — |
| Carcinoma, Pancreatic | Pancreatic Carcinoma | ONTOLOGY_EXACT | 0.98 |
Interventions
Interventions (1)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| CPAP machine | Device | — | UNRESOLVED |
Design
Arms and outcomes
Arms (2)
- type
- NO_INTERVENTION
- label
- standard breath hold
- description
- 1. Breath-hold CT and 4D-CT without CPAP 2. Breath-hold MRI and 4D-MRI without CPAP a) T1-weighted, T2-weighted, Dixon fat/water, and ultra-short TE images
- type
- EXPERIMENTAL
- label
- CPAP intervention
- description
- 1. Breath-hold CT without CPAP 2. 4D-CT with and without CPAP 3. 4D-MRI with CPAP 1. T1-weighted, T2-weighted, Dixon fat/water, and ultra-short TE images
- interventionNames
- Device: CPAP machine
Primary outcomes (2)
- measure
- Assessment of the Internal Target Volume on 4D-MR and 4D-CT
- timeFrame
- baseline
- description
Eligibility
Eligibility (as posted)
- Sex
- All
- Minimum age
- 18 Years
Show eligibility criteria text
Inclusion Criteria: * Patients have liver or pancreas tumors (either primary tumors or metastases) and are scheduled to be treated with radiotherapy (either 3D conformal or intensity-modulation radiotherapy (IMRT) with conventional or hypo- fractionation). * KPS \> 70 * If a biopsy is performed, the patient is at least 1 week post-biopsy. * The patient's age must exceed 18 years. * The patients must be able to commit to T1-weighted, T2-weighted, Dixon fat and water, ultrashort-TE, and other clinical or research MR sequence images prior to treatment. * CPAP Eligibility: CPAP is a safe, effective form of therapy with rare complications. Relative contraindications include patients with bullous lung disease, fibrotic lung disease, Claustrophobia and recurrent sinus or ear infections. The absolute contraindications include obtundation /unconsciousness, chest wall trauma, suspected pneumothorax, persistent nausea/vomiting, active upper GI bleeding, history of recent gastric surgery, facial anomalies/trauma \[15,16\]. If there is any question about the above history and medical problems, the subject will be referred to a pulmonologist for consultation. * The patients with above contraindications are not CPAP eligible and are enrolled in Arm 1 for the protocol without CPAP * The eligible patients are enrolled in Arm 2 for the protocol with CPAP. Exclusion Criteria: * Any medical condition, which would make the imaging studies unsafe or poorly tolerated * Known allergic reaction to contrast or shellfish * Implanted metal devices or foreign bodies that serve as a contraindication to MR imaging * Creatinine \> 1.4 mg/dl and Creatinine clearance \< 20 mg/dl. * Uncontrolled, clinically significant cardiac arrhythmias * Severe claustrophobia * Pregnant female * KPS \<70
References
Publications (0)