Clinical trial · Interventional
Evaluation of Virtual Touch Tissue Imaging Quantification (VTIQ - 2D-SWE) in the Assessment of BI-RADS® 3 and 4 Lesions
Evaluation of Virtual Touch Tissue Imaging Quantification (VTIQ - 2D-SWE) in the Assessment of BI-RADS® 3 and 4 Lesions: Can Patient Selection for Biopsy be Improved? - A Confirmatory Multi-Center-Study
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
The primary aim of this study is to evaluate if VTIQ in addition to BI-RADS® categorization can improve the diagnostic accuracy with respect to detection of malignancies, in particular for BI-RADS® categories 3 and 4a. The idea of the study is to restage all patients in categories 3 and 4a according to a predefined VTIQ cut-off value of ≥ 3.5 m/s (37 kPa).
Conditions
Conditions (1)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Breast Neoplasms | Breast Neoplasm | ONTOLOGY_EXACT | 0.98 |
Interventions
Interventions (1)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| Ultrasound- Virtual Touch Tissue Imaging Quantification | Device | — | UNRESOLVED |
Design
Arms and outcomes
Arms (4)
- type
- OTHER
- label
- BI-RADS 3
- description
- Intervention: Ultrasound- Virtual Touch Tissue Imaging Quantification
- interventionNames
- Device: Ultrasound- Virtual Touch Tissue Imaging Quantification
- type
- OTHER
- label
- BI-RADS 4a
- description
- Intervention: Ultrasound- Virtual Touch Tissue Imaging Quantification
- interventionNames
- Device: Ultrasound- Virtual Touch Tissue Imaging Quantification
- type
- OTHER
- label
- BI-RADS 4b
- description
- Intervention: Ultrasound- Virtual Touch Tissue Imaging Quantification
Eligibility
Eligibility (as posted)
- Sex
- Female
- Minimum age
- 18 Years
Show eligibility criteria text
Inclusion Criteria: * Female * Age ≥18 years * Patients with a lesion ≥ 0.5 cm in largest diameter size, initially scored BI-RADS® 3, 4a, 4b or 4c in B-mode ultrasound * Informed consent about histological examination (core cut biopsy (CCB), vacuum-assisted biopsy (VAB), fine needle aspiration (FNA) or surgery) has already been given in the course of clinical routine * Signed informed consent of study participation Exclusion Criteria: * Pregnant or lactating women * Women with breast implants on the same side as the lesion * Women that underwent local radiation or chemotherapy within the last 12 months * Women with history of breast cancer or breast surgery in the same quadrant * Lesions in or close to scar tissue (\< 1cm) * Skin lesions or lesions that have been biopsied previously * Lesion larger than 4 cm in the longest dimension * No lesion should be included when more than 50% of the lesion is further down than 4 cm beneath the skin level.
References
Publications (14)
- BACKGROUNDBarr RG, Zhang Z. Shear-wave elastography of the breast: value of a quality measure and comparison with strain elastography. Radiology. 2015 Apr;275(1):45-53. doi: 10.1148/radiol.14132404. Epub 2014 Nov 24. PMID 25426770
- BACKGROUNDBarr RG, Zhang Z. Effects of precompression on elasticity imaging of the breast: development of a clinically useful semiquantitative method of precompression assessment. J Ultrasound Med. 2012 Jun;31(6):895-902. doi: 10.7863/jum.2012.31.6.895. PMID 22644686
- BACKGROUNDGolatta M, Schweitzer-Martin M, Harcos A, Schott S, Junkermann H, Rauch G, Sohn C, Heil J. Normal breast tissue stiffness measured by a new ultrasound technique: virtual touch tissue imaging quantification (VTIQ). Eur J Radiol. 2013 Nov;82(11):e676-9. doi: 10.1016/j.ejrad.2013.06.029. Epub 2013 Aug 8. PMID 23932637
- BACKGROUNDGolatta M, Schweitzer-Martin M, Harcos A, Schott S, Gomez C, Stieber A, Rauch G, Domschke C, Rom J, Schutz F, Sohn C, Heil J. Evaluation of virtual touch tissue imaging quantification, a new shear wave velocity imaging method, for breast lesion assessment by ultrasound. Biomed Res Int. 2014;2014:960262. doi: 10.1155/2014/960262. Epub 2014 Mar 31. PMID 24800257
- BACKGROUNDTozaki M, Saito M, Benson J, Fan L, Isobe S. Shear wave velocity measurements for differential diagnosis of solid breast masses: a comparison between virtual touch quantification and virtual touch IQ. Ultrasound Med Biol. 2013 Dec;39(12):2233-45. doi: 10.1016/j.ultrasmedbio.2013.07.012. Epub 2013 Sep 21. PMID 24063961
- BACKGROUNDBarr RG, Nakashima K, Amy D, Cosgrove D, Farrokh A, Schafer F, Bamber JC, Castera L, Choi BI, Chou YH, Dietrich CF, Ding H, Ferraioli G, Filice C, Friedrich-Rust M, Hall TJ, Nightingale KR, Palmeri ML, Shiina T, Suzuki S, Sporea I, Wilson S, Kudo M. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 2: breast. Ultrasound Med Biol. 2015 May;41(5):1148-60. doi: 10.1016/j.ultrasmedbio.2015.03.008. Epub 2015 Mar 18.