Clinical trial · Interventional
Study of the Outcomes of Intraoperative Margin Assessment With MarginProbe
A Phase II Study of the Outcomes of Intraoperative Margin Assessment With Adjunctive Use of MarginProbe in Addition to Standard
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
The combination of breast conserving surgery (lumpectomy) with radiation therapy has been shown to result in equivalent overall survival rates compared to mastectomy for the local treatment of breast cancer. As a result, the majority of patients diagnosed with breast cancer in the United States undergo lumpectomy as their primary surgical therapy. Multiple studies have demonstrated the association between positive lumpectomy margins and an increased risk of ipsilateral breast tumor recurrence, even with postoperative radiation. Studies report 20-40% of lumpectomy procedures result in one or more involved (positive) surgical margins, leading to the need for further surgery, emotional distress, poorer cosmesis, delay to adjuvant treatments, and increased cost. Current available intraoperative margin assessment techniques include specimen Xray, gross pathology, frozen section, and touch prep cytology. To reduce the incidence of positive margins, the MarginProbe (Dune Medical Devices, Caesarea, Israel) was developed to provide real-time, intraoperative assessment of the presence of tumor at the lumpectomy margin. In the current study, the investigators aim to determine the effectiveness of MarginProbe as an adjunctive tool to standard practice for intraoperative identification of tumor at lumpectomy margins, and its ability to reduce positive margins and decrease the need for additional surgical procedures.
Conditions
Conditions (1)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Breast Cancer | Malignant Breast Neoplasm | CURATED_EXACT | 0.92 |
Interventions
Interventions (1)
| Intervention | Type | Mapped drug | Match |
|---|---|---|---|
| MarginProbe | Device | — | UNRESOLVED |
Design
Arms and outcomes
Arms (1)
- type
- EXPERIMENTAL
- label
- MarginProbe
- description
- Single arm study - MarginProbe in addition to standard procedure
- interventionNames
- Device: MarginProbe
Primary outcomes (1)
- measure
- Percentage of patients with histologically positive surgical margins
- timeFrame
- 2 weeks after surgery
Secondary outcomes (2)
- measure
- Percentage of patients who undergo a second surgery after initial lumpectomy.
- timeFrame
- 2 weeks after surgery
- measure
- False positive and false negative rate of Intraop MarginProbe results compared to histologic evaluation
Eligibility
Eligibility (as posted)
- Sex
- Female
Show eligibility criteria text
Inclusion Criteria: 1\. Subjects able to read and understand the informed consent Exclusion Criteria: 1\. Subjects unable to read or understand the informed consent.
References
Publications (8)
- BACKGROUNDMoran MS, Schnitt SJ, Giuliano AE, et al. JCO Feb 10, 2014.
- RESULTAllweis TM, Kaufman Z, Lelcuk S, Pappo I, Karni T, Schneebaum S, Spector R, Schindel A, Hershko D, Zilberman M, Sayfan J, Berlin Y, Hadary A, Olsha O, Paran H, Gutman M, Carmon M. A prospective, randomized, controlled, multicenter study of a real-time, intraoperative probe for positive margin detection in breast-conserving surgery. Am J Surg. 2008 Oct;196(4):483-9. doi: 10.1016/j.amjsurg.2008.06.024. PMID 18809049
- RESULTPappo I, Spector R, Schindel A, Morgenstern S, Sandbank J, Leider LT, Schneebaum S, Lelcuk S, Karni T. Diagnostic performance of a novel device for real-time margin assessment in lumpectomy specimens. J Surg Res. 2010 May 15;160(2):277-81. doi: 10.1016/j.jss.2009.02.025. Epub 2009 Mar 31. PMID 19628225
- RESULTRivera RJ, Holmes DR, Tafra L. Analysis of the Impact of Intraoperative Margin Assessment with Adjunctive Use of MarginProbe versus Standard of Care on Tissue Volume Removed. Int J Surg Oncol. 2012;2012:868623. doi: 10.1155/2012/868623. Epub 2012 Dec 26. PMID 23326653
- RESULTThill M, Dittmer C, Baumann K, Friedrichs K, Blohmer JU. MarginProbe(R)--final results of the German post-market study in breast conserving surgery of ductal carcinoma in situ. Breast. 2014 Feb;23(1):94-6. doi: 10.1016/j.breast.2013.11.002. Epub 2013 Dec 2. PMID 24291375
- RESULTSchnabel F, Boolbol SK, Gittleman M, Karni T, Tafra L, Feldman S, Police A, Friedman NB, Karlan S, Holmes D, Willey SC, Carmon M, Fernandez K, Akbari S, Harness J, Guerra L, Frazier T, Lane K, Simmons RM, Estabrook A, Allweis T. A randomized prospective study of lumpectomy margin assessment with use of MarginProbe in patients with nonpalpable breast malignancies. Ann Surg Oncol. 2014 May;21(5):1589-95. doi: 10.1245/s10434-014-3602-0. Epub 2014 Mar 5. PMID 24595800
- RESULTPolice AM. Routine use of a real time margin assessment device. Poster Abstract presented at the 31st Annual Miami Breast Cancer Conference; May 2014.