Clinical trial · Observational
Reduced Planning Target Volume (PTV) Margins for the Treatment of Prostate Cancer Using the Calypso 4D Localization System
Reduced PTV Margins for the Treatment of Prostate Cancer With IMRT Using Real-Time, State-of-the-Art Motion Tracking With the Calypso 4D Localization System: A Feasibility Study
- Source
- ClinicalTrials.gov
- Retrieved
- Sep 8, 2026
- Layer
- normalized (units and labels harmonized; values unchanged)
- Run
- ING-CLINICALTRIALS-20260908-000001
Summary
Brief summary (as posted)
This prospective study evaluates the clinical utility of a novel real-time localization system allowing for smaller volumes of normal tissue to be included in radiation field and determines dosimetric parameters and adverse effect profiles of radiation therapy using this technology. Subjects will have beacon transponders implanted into the prostate to more precisely localize the position of the organ during radiation therapy. Hypothesis: 1. Treatment with highly targeted radiation therapy can be delivered in a daily treatment time consistent with routine clinical practice. 2. Highly targeted radiation therapy with reduced PTV margin will result in a significant decrease in rectal and bladder volume treated.
Conditions
Conditions (1)
Free-text conditions as registered, with the CancerIndex entity they were reconciled to and the match type.
| Condition (as posted) | Mapped entity | Match | Confidence |
|---|---|---|---|
| Prostate Cancer | Malignant Prostate Neoplasm | CURATED_EXACT | 0.92 |
Interventions
Interventions (0)
Data not yet available
Design
Arms and outcomes
Arms (0)
[]Primary outcomes (1)
- measure
- Radiation therapy with reduced treatment margins can be adopted as feasible for routine clinical use
- timeFrame
- Approximately 8.5 weeks (43 fractions per pt.)
- description
- During each radiation treatment fraction, therapists will record set up time, treatment time, total time and number of treatment interventions (repositioning/pausing) as well as the duration of the intervention caused by organ/target motion beyond planning target volume (PTV) margin using real time localization and tracking.
Secondary outcomes (2)
- measure
- Analyze dosimetric characteristics of treatment planning
- timeFrame
- usually within the first 2 weeks after beacon placement (done at simulation CT)
- description
- Standard methods vs. reduced planning target volume expansions will be analyzed: 1. Dose Volume Histogram (DVH), bladder and rectum 2. Volume receiving 77.4Gy by the prescription dose (V77.4Gy), V70Gy, and V50Gy of bladder and rectum
- measure
- Assess incidence of acute bladder and rectal toxicity
Eligibility
Eligibility (as posted)
- Sex
- Male
- Minimum age
- 40 Years
Show eligibility criteria text
Inclusion Criteria: * Histologically confirmed adenocarcinoma of the prostate * Low Risk: T1a, T1b, T1c, T2a; Gleason Score less than 7, PSA less than or equal to 10 * Intermediate Risk: T2b, T2c; Gleason Score less than or equal to 7, PSA less than or equal to 15 * Ability to comply with study schedule * Age 40 or older * Zubrod PS 0 or 1 * Signed informed consent Exclusion Criteria: * Node positive or metastatic prostate cancer * Prior treatment of prostate cancer with surgery, chemotherapy, cryotherapy or brachytherapy * History of prior pelvic radiotherapy * History of abdominoperineal resection * History of HIV infection * History of chronic prostatitis or chronic cystitis * History of bleeding disorder or any active anticoagulation (excluding ASA) * PT or INR outside normal range for institution * Active implanted devices such as cardiac pacemakers and automatic defibrillators. * Prosthetic implants in the pelvic region that contain metal or conductive materials (eg., an artificial hip). * Patients with maximum anterior-posterior separation through the torso minus the height of the center of the prostate greater than 17 cm (technical reason for Calypso System, see appendix 8). * Prior history of androgen deprivation therapy has been deleted and these patients are allowed on study.
References
Publications (0)
Data not yet available